COTS-NTDS-IIU_SYB

Synchro input & Switch board(SYB) is a module that has the function to select and switch the analog synchro signal input from inertial navigation system(INS), Electromagnetic Log(EM-LOG) and simulation boards, and transmit it to Synchro Booster board. It has been designed to meet the IIU requirements of the intagrated combat system for Submarine.

견적문의

 

Specifications

FunctionsDescriptionsRemarks
Synchro Inputs (@ Simulation mode) 90Vl-l/400Hz 3P 2CH(1X/36X)
I90Vl-l/400Hz 3P 2CH(1X/36X)
90Vl-l/400Hz 3P 2CH(1X/36X)
SIM.
INS1
INS2
Synchro Inputs (@ Normal mode)90Vl-l/400Hz 3P 2CH(1X/36X)
90Vl-l/400Hz 3P 2CH(1X/36X)
MAIN 
AUX
Analog Outputs90Vl-l/400Hz 3P(1X)
90Vl-l/400Hz 3P(36X)
COARSE
FINE
GPIO
GPIO1 x Output : Dry-contact
1 x Output : LOGIC
1 x Output : LED
FAILURE(BIT)
CARD CHECK
STATUS
I/O Connectors09031646951 x 1for GPIO, DC in
for AC 3P i/o
Power Supply115V/400Hz, +12V, +10V, +6V-
Power ConsumptionMax. 1.5 Watts24V/62.5mA Max. 
Operating Temperature-40 ~ 85°C-
WeightMax. 1.0KgIncluded frame
Key AngleN/A-
Form Factors3U, 2 slots (100 x 167 x 40mm) Customized
Frame, WedgeLokForward type-